UNDERFLOOR HEATING SYSTEM

IMPLEMENTATION

High density (30 or 40 density) thermal insulating materials (Cetin special production modulation panel) are laid on floor concrete. So heat and sound insulating will be provided between floor. (This situation has very importance in case of individual heating with combi-boiler). Under-floor heating pipes in lengths and shapes determined in the project with heat calculations shall be installed on set styropor. Alum concrete shall be laid after pressure and leakage tests on the installed pipes. Floor coating shall be made after the alum concrete dries. (Ceramic, parquet, carpet, marble etc.)

HISTORYCALLY

The first implementations in under-floor heating dates back to B.C.1200 years. Under-floor heating implementations were suspended for a period because long-life materials under flooring at the systems made with water couldn’t found in 1900s. (Under-floor heating systems with copper wire are seen at the Kocatepe Mosque in 1970s). Until production of the plastic technology heat resistant long life (ppr-c, pex, albex etc.) pipes, under-floor heating installation is spread again nowadays because the lives of the plastic pipes is longer than the building life under floor covering

ECONOMICALLY
The cost of under-floor heating system has same price with the radiator and other heating systems. Since the insulating material used in under-floor heating system (set styropor or modulation panel) is insulating material not heating, under-floor heating installation costs in more economical conditions when we add insulating material cost in other systems.
CLEAN AND HEALTHY
Since the under-floor heating system does not create burnt dust, it doesn’t make smut at tulle curtains and walls, not cause dirtying. It dries the floor rapidly after surface cleaning on the floors (door mat etc.). It prevents the floor stay damp. It prevents production of bacteria caused by the damp environments. Under- floor heating is the heating system most convenient to human anatomy.
ARCHITECTURAL ADVANTAGES
It provides saving up to % 5 and opportunity of comfortable decoration since there are not heaters (radiator, apparatus etc.) in front of the glasses and interior locations. Screens, wall boards and independent sections (secretary office, inspection room, bureau, office etc.) may be constituted in wide volume locations. Heating of these sections does not be a problem.
FUEL SAVING
Heat Condensation at room ceiling which can’t be prevented in the other systems does not exists in under –floor heating systems. Further being of operating temperature low (maximum 55°C) provided fuel savings of up to 35% when natural gas fuel condensation devices are used.
                           
HOME UNDERFLOOR HEATING MODULATION PANEL INSULATION GROUP PRODUCTS
Corporate & Career Defination Defination Defination Underfloor Heating
Contact Application Technical Specifications Technical Specifications Butopor
  Calculations Why Foil Covering? Construction Chemicals Butopipe
Butovalve
CETİN ENGINEERING - since 1993.